calcs/concrete-beam/results.json
smillmorel 8f91baee41 Use Pint and unit-free variable names in concrete-beam
Convert input parsing to Pint (matching the other calculations), carry
units in the YAML values, and drop unit suffixes from input keys, local
variables, results keys, the Typst sheet, and tests.
2026-09-21 12:44:28 -04:00

49 lines
880 B
JSON

{
"tool": "concrete_beam",
"version": "0.1",
"project": "Deer Creek Shoring",
"prepared_by": "Conemco Engineering",
"values": {
"span": 16.0,
"tributary": 6.25,
"D": 55.0,
"L": 20.0,
"self_weight": 0.1,
"wD": 0.44375,
"wL": 0.125,
"wu": 0.7325,
"Mu": 23.44,
"Vu": 5.86,
"bw": 8.0,
"h": 12.0,
"d": 9.5,
"fc": 3.0,
"fy": 60.0,
"As": 0.62,
"a": 1.823529,
"et": 0.010285,
"phi": 0.9,
"Mn": 26.623529,
"phiMn": 23.961176,
"As_min": 0.253333,
"Vc": 8.325383,
"phiVc": 6.244037
},
"checks": {
"flexure": {
"demand": 23.44,
"capacity": 23.961176,
"ok": true
},
"minimum_steel": {
"demand": 0.253333,
"capacity": 0.62,
"ok": true
},
"shear": {
"demand": 5.86,
"capacity": 6.244037,
"ok": true
}
}
}