{ "tool": "concrete_beam", "version": "0.1", "project": "Deer Creek Shoring", "prepared_by": "Conemco Engineering", "values": { "span": 16.0, "tributary": 6.25, "D": 55.0, "L": 20.0, "self_weight": 0.1, "wD": 0.44375, "wL": 0.125, "wu": 0.7325, "Mu": 23.44, "Vu": 5.86, "bw": 8.0, "h": 12.0, "d": 9.5, "fc": 3.0, "fy": 60.0, "As": 3.141593, "a": 9.239978, "et": -0.000378, "phi": 0.65, "Mn": 76.65503, "phiMn": 49.82577, "As_min": 0.253333, "Vc": 8.325383, "phiVc": 6.244037, "cover": 1.5, "stirrup_size": 3, "stirrup_spacing": 8.0, "stirrup_db": 0.375, "bar_size": 8, "n_bars": 4, "bar_db": 1.0, "top_bar_size": 8, "n_top_bars": 2, "top_bar_db": 1.0 }, "checks": { "flexure": { "demand": 23.44, "capacity": 49.82577, "ok": true }, "minimum_steel": { "demand": 0.253333, "capacity": 3.141593, "ok": true }, "shear": { "demand": 5.86, "capacity": 6.244037, "ok": true } } }