{ "tool": "concrete_beam", "version": "0.1", "project": "Deer Creek Shoring", "prepared_by": "Conemco Engineering", "values": { "span": 16.0, "tributary": 6.25, "D": 55.0, "L": 20.0, "self_weight": 0.1, "wD": 0.44375, "wL": 0.125, "wu": 0.7325, "Mu": 23.44, "Vu": 5.86, "bw": 8.0, "h": 12.0, "d": 9.5, "fc": 3.0, "fy": 60.0, "As": 0.613592, "a": 1.804683, "et": 0.010423, "phi": 0.9, "Mn": 26.377285, "phiMn": 23.739557, "As_min": 0.253333, "Vc": 8.325383, "phiVc": 6.244037, "cover": 1.5, "stirrup_size": 3, "stirrup_spacing": 6.0, "stirrup_db": 0.375, "bar_size": 5, "n_bars": 2, "bar_db": 0.625, "top_bar_size": 4, "n_top_bars": 2, "top_bar_db": 0.5 }, "checks": { "flexure": { "demand": 23.44, "capacity": 23.739557, "ok": true }, "minimum_steel": { "demand": 0.253333, "capacity": 0.613592, "ok": true }, "shear": { "demand": 5.86, "capacity": 6.244037, "ok": true } } }