"tool": "concrete_beam2",
"version": "0.1",
"project": "Deer Creek Shoring",
"prepared_by": "Conemco Engineering",
"values": {
"span_ft": 16.0,
"tributary_ft": 6.25,
"D_psf": 55.0,
"L_psf": 20.0,
"self_weight_klf": 0.1,
"wD_klf": 0.44375,
"wL_klf": 0.125,
"wu_klf": 0.7325,
"Mu_kipft": 23.44,
"Vu_kip": 5.86,
"bw_in": 8.0,
"h_in": 12.0,
"d_in": 12.0,
"fc_ksi": 3.0,
"fy_ksi": 50.0,
"As_in2": 0.62,
"a_in": 1.519608,
"et": 0.017137,
"phi": 0.9,
"Mn_kipft": 29.037173,
"phiMn_kipft": 26.133456,
"As_min_in2": 0.384,
"Vc_kip": 10.516273,
"phiVc_kip": 7.887205
},
"checks": {
"flexure": {
"demand": 23.44,
"capacity": 26.133456,
"ok": true
},
"minimum_steel": {
"demand": 0.384,
"capacity": 0.62,
"ok": true
},
"shear": {
"demand": 5.86,
"capacity": 7.887205,
"ok": true
}
}
}