29 lines
1.3 KiB
YAML
29 lines
1.3 KiB
YAML
|
|
# Project name shown in the Typst report header.
|
||
|
|
project: "Interior Bearing Wall"
|
||
|
|
# Person or organization shown in the Typst report footer.
|
||
|
|
prepared_by: "Conemco Engineering"
|
||
|
|
|
||
|
|
# Axial load (ASD) checked against the allowable column capacity.
|
||
|
|
P: "400 lbf"
|
||
|
|
|
||
|
|
# Stud geometry (actual dimensions of a nominal 2x4).
|
||
|
|
length: "6 ft" # L, total stud length
|
||
|
|
width: "1.5 in" # b, actual 2x4 width
|
||
|
|
depth: "3.5 in" # d, actual 2x4 depth
|
||
|
|
Ke: 1.0 # effective-length factor, pinned-pinned (NDS 3.7.1.2 / Appendix G)
|
||
|
|
|
||
|
|
# Species and grade label shown in the report. "SP" is read as Southern Pine
|
||
|
|
# (SYP) per NDS Supplement Table 4B; confirm if SPF or SPF-S was intended.
|
||
|
|
species_grade: "SP (Southern Pine) No. 2"
|
||
|
|
|
||
|
|
# NDS Supplement reference design values for Southern Pine (SYP) No. 2, dimension lumber.
|
||
|
|
Fc: "1450 psi" # compression parallel to grain (F_c)
|
||
|
|
E: "1400000 psi" # modulus of elasticity (E)
|
||
|
|
E_min: "510000 psi" # 5th-percentile modulus (E_min)
|
||
|
|
|
||
|
|
# Adjustment factors (NDS Table 4.3.1). All 1.0 except size factor for this example.
|
||
|
|
CD: 1 # load duration factor (1.0 = normal/occupancy duration, NDS 2.3.2)
|
||
|
|
CM: 1 # wet service factor (dry, moisture < 19%, NDS 4.3.3)
|
||
|
|
Ct: 1 # temperature factor (< 100 deg F, NDS 4.3.4)
|
||
|
|
CF: 1.15 # size factor for compression, 2x4 (NDS 4.3.6)
|
||
|
|
Ci: 1 # incising factor (NDS 4.3.8)
|